Feb 20, 2017 to measure negative sequence impedance of an alternator, we short the white and blue phases, measure the current and then divide it by the voltage of the red phase. Short questions and answers ee1251 electrical machines ii. Electro motive force emf or synchronous impedance method. What is regulation of alternator by synchronous impedance method. Electrical machines ii emf induced in the armature conductors. Jun 11, 2015 voltage regulation of an alternator is defined as the change in terminal voltage from no load to full load expressed as a percentage of rated voltage when the load at a given power factor is removed with out change in speed and excitation. Sm23 synchronous impedance method or emf method duration. The usual method of measuring synchronous impedance is by the short circuit test, which consists in running the alter nator at normal speed with its armature short circuited thru an ammeter and leads of negligible resistance and inductance. The dc generator generates a small amount of electricity just enough to excite the field coils of the connected alternator to generate electricity.
Why almost all large size synchronous machines are constructed with rotating field system type. Contents defination methods to determine voltage regulation 1 synchronous impedance method 2 mmf method 3 zero power factor method 3. Voltage regulation of alternator and solved example youtube. What is the difference between salient pole alternator and cylindrical rotor type alternator. Thetwocomponents,resistanceand inductance,form a resultantimpedancewhichmay be designated asthe workingimpedanceof the armature. Voltage regulation of synchronous generator voltage. Full text of the measurement of synchronous impedance. How is the regulation of alternator predetermined by slip test. Find the synchronous impedance and reactance of a 1phase alternator in which a given field current produces an armature current of 200 a on shortcircuit and a generated e.
The voltage induced in the conductors is an alternating one and is converted into dc using commutator segments as shown in the figure. If you know the answer to this question, please register to join our limited beta program and. Find out how your company can benefit from plm built on salesforce. May 04, 2018 synchronous reactance of alternator synchronous impedance of an alternator synchronous reactance xd. If you have more than 1 generator that normally operates interconnected with. Voltage equation of alternator synchronous reactance. Experimental determination of equivalent circuit parameters. To determine the voltage regulation of an alternator by the synchronous impedance method.
In the paper, the author is presenting comparatively the application of. Apr 20, 2016 normally for voltage regulation calculation, we use methods like. In this test, it is assumed that the alternator is star connected with the dc field winding open as shown in the circuit diagram below. Synchronous generator, reactance evaluation, numerical methods, finite element method fem 1. Synchronous impedance method armature turn or mmf method zero pf or potier method synchronous impedance method gives result which is higher than the original value. Why synchronous impedance is not constant for given alternator.
Voltage regulation of alternator emf and mmf methods duration. Hence, the value or regulation so obtained is always more, than that found from an actual test. The synchronous motor operates at a precise synchronous speed, and hence is a constantspeed motor. The brush 1 always makes contacts with a conductor moving under north pole and the brush 2. Oct 22, 2017 a no load voltage is induced in the stator coils of alternator when rotor is rotated by a prime mover. Inspite of these short comings, due to the simplicity of constructions the asa modified from of m. What is regulation of alternator by synchronous impedance. For any synchronous generator or alternator, mmf is required, which is a product of field current and turns of the field winding for two separate purposes. Answer to what is meant by synchronous impedance of an alternator.
The following are the principal advantages of the rotating field system type construction of synchronous machines. A guide for synchronous generator parameters determination using dynamic simulations based on ieee standards conference paper pdf available october 2010 with 7,439 reads how we measure reads. C is called the unsaturated value of the synchronous impedance. Why synchronous impedance is not constant for given. This method of excitation consists of a smaller directcurrent dc generator fixed on the same shaft with the alternator. Few requirements are there to calculate voltage regulation of synchronous machine by e. Estimation of optimal value of synchronous impedance using. A convenient way to compare the voltage behaviour of two generators is by their voltage regulation vr. Mmf method of voltage regulation its phasor diagram.
Objective questions on alternator page 2 electrical. Start by assuming that the generator is connected to a lagging power factor load. Which of the method more accurate for determine the voltage. To study the synchronization of the alternator with infinite bus bar.
The open circuit characteristic is the graph of the circuit voltage and the field current. Voltage regulation of synchronous machine alternator by. Blondels two reaction theory, phasor diagram, direct axis and quadrature axis synchronous reactances, power angle characteristics, slip test. The complex addition of resistance, r and synchronous reactance, jx s can be represented together by a single.
The synchronous impedance method is based on the concept of replacing the effect of armature reaction by an imaginary reactance the magnetomotive force mmf. Now lets calculate voltage regulation of synchronous machine by e. Apr 28, 2015 determination of voltage regulation method of synchronous machine 1. Pdf a new approach for synchronous generator terminal. Bhupendra desia rightly explained about the differences. Voltage regulation of alternator using synchronous impedance. An introduction to synchronous alternator free download as powerpoint presentation. When a balanced load is connected across stator winding a balanced set of 3 phase currents flow with a phase relation with no load voltage depen. Contents defination methods to determine voltage regulation 1 synchronous impedance method 2 mmf method 3 zero power factor method. Alternator if there are n ph turns per phase, then synchronous generator e ph 4. Negative and zero sequence impedance of alternator physics. In a synchronous alternator the rate at which the synchronous power p varies with load angle. Adams engineering college, paloncha eee department emii lab experiment no.
A new approach for synchronous generator terminal voltage control comparison with a standard industrial controller article pdf available in electric power systems research 817. In this method, the armature reaction is treated as another armature leakage reactance. Voltage regulation of alternator using synchronous impedance method voltage regulation of synchronous generator calculations. Short questions and answers ee1251 electrical machines ii 1. Solved regulation of alternator by synchronous impedance. Synchronous machines can also be used as motors, but they are usually built in very large sizes. For calculating the regulation, the synchronous method requires the following data. Zero power factor lagging characteristics for potier method. Methods to determine voltage regulation of alternator q1. A variation of this system is a type of alternator which uses direct. Which method for finding percentage regulation is called pessimistic method. What is meant by synchronous impedance of an alternator. Voltage regulation of alternator by mmfampere turn method. Derivation of various power conditions in alternators and.
Masters thesis, memorial university of newfoundland. What is the difference between induction generator and. Mmf method of voltage regulation mmf method is also known as ampere turn method. Mmf method is used for determining the voltage regulation of an alternator or synchronous generator is also called ampere turns method or rotherts mmf method. C is a plot of shortcircuit armature current versus the field current.
An understanding of how load changes effect the operation of the generator can be obtained by considering the simplified phasor diagram. Synchronous impedance method the synchronous impedance method or emf method is based on the concept of replacing the effect of armature reaction by an imaginary reactance. This mmf method is based on the results of open circuit test and short circuit test on an alternator. An introduction to synchronous alternator rectifier inductor. Jun 11, 2015 voltage regulation of synchronous generator by mmf method. Reacta7tcbofaiterhators contents page i introductory ii statementofproblem general 3 reactance 4 synchronousreactanceofalternators5. May 08, 2018 voltage regulation of alternator by emf method and solved problem duration.
Phasor diagrams for standalone synchronous generators. Power output per phase of cylindrical rotor generator. Methods to determine voltage regulation of alternator. Mmf method for determining voltage regulation of alternator. Ghanim, daw farag daw 2012 experimental determination of equivalent circuit parameters for a laborator salientpole synchronous generator. This method is also known as synchronous impedance method.